Clinical Tools & Reference Center

Standard Oxygen Calculator

Portable & vehicle-mounted oxygen · Transport planning
Bay Medic Star of Life
ESTIMATE ONLY — VERIFY BEFORE USEEstimates use provisional cylinder factors and a 500 PSI reserve. Verify actual gauge pressure, cylinder specifications, total oxygen draw and required backup supply. Actual duration may vary with regulator performance, gauge accuracy, leaks, changing flow and delays. Follow agency reserve and replacement requirements; this tool is not dispatch clearance. Clinical validation and agency approval are required before operational use.

1. Enter total oxygen flow

Enter the actual oxygen flowmeter setting in LPM (0.5–25). If multiple devices draw from the same cylinder, enter their combined continuous oxygen flow. Use the prescribed flow; do not reduce it to extend cylinder duration.

Enter the flow rate to begin.

2. Estimate time on cylinder

From switching to the cylinder through loading.

GPS estimate, including expected delays.

Unloading and handoff until switching oxygen sources.

Total estimated oxygen-use time

Pickup + travel + offload

—

Enter the expected time the oxygen cylinder will be in use. Blank time fields count as zero.

Include delays and extra time for safety. During the call, enter the current gauge PSI and only the time still remaining. This calculator is not a live countdown.

3. Enter actual cylinder gauge pressures

Enter the actual gauge pressure for each cylinder you want to check. Each result assumes that cylinder alone supplies the selected flow and time; no automatic tank switching or combined supply calculation.

Normal planning always stops at 500 PSI. This choice changes only the separate red residual-gas estimate. It is not a safe operating limit or permission to delay cylinder replacement.

D Cylinder
(Portable)
Factor 0.16
—min until 500 PSI
M Cylinder
(Vehicle Mounted)
Airgas 125 · factor 1.56
—min until 500 PSI
Backup D Cylinder
(Portable Spare)
Factor 0.16 · optional
—min until 500 PSI
E Cylinder
(Portable)
Factor 0.28 · optional
—min until 500 PSI

Normal planning stops at 500 PSI. Green minutes indicate modeled oxygen time above reserve, not clearance to take a call. Red reserve estimates model only the gas below 500 PSI down to the selected theoretical endpoint (200, 100 or 0 PSI); without a transport plan, that portion is displayed separately even above 500 PSI. Use actual gauge readings and approved reserve, replacement and backup requirements. Each cylinder is calculated independently.

Method, assumptions and limitations

For continuous-flow oxygen, estimated draw equals total flow in L/min. Normal minutes = max(0, gauge PSI − 500) × cylinder factor ÷ estimated draw, rounded down. The separate residual model = max(0, min(gauge PSI, 500) − selected endpoint) × cylinder factor ÷ estimated draw, rounded down. With no transport times entered and a gauge above 500 PSI, it shows only the hypothetical portion between 500 PSI and the selected endpoint; at or below 500 PSI it shows the modeled residual from the current gauge reading. Neither is routine available oxygen. The selectable 200, 100 and 0 PSI endpoints are mathematical comparison assumptions, not validated minimum operating pressures or guaranteed usable durations. The 0 PSI setting represents mathematical depletion only.

Transport estimate: total planned minutes = pickup + travel + offload. Estimated cylinder pressure at the end = starting PSI − (total flow × total minutes ÷ cylinder factor), rounded down for display. This is a constant-flow mathematical model, not a measurement. The time margin compares planned minutes only with the normal 500 PSI reserve endpoint; the red residual-gas model is never included in the transport plan. If the plan exceeds the modeled normal time, the projection is replaced with a warning and the shortfall in whole minutes (rounded up). No projected gauge reading is shown for an insufficient cylinder. If the mathematical model predicts depletion, it also warns of the theoretical zero-pressure point, which is not usable oxygen time. If the plan reaches the reserve exactly, it shows an explicit no-margin warning. A modeled surplus does not establish sufficient oxygen for a transport; account for backup, contingency, other oxygen use and agency readiness requirements.

The residual calculation is not validated at low cylinder pressure. A regulator or flowmeter may fail to maintain delivery above the selected residual reference; gauge error is especially consequential near empty. Maintain backup oxygen and follow approved emergency procedures. Do not use the red value to decide to postpone changeover.

For standard continuous-flow oxygen only. Enter the combined flow for all simultaneous consumers on the same cylinder, if known and constant. Do not use this tool for HFNC, CPAP, ventilators, demand/pulse-dose systems or other equipment with unverified oxygen consumption.

Actual endurance may differ because of gauge accuracy, temperature, leaks, changing flow, other oxygen use and transport delays. Verify the cylinder factors with the supplier. A nonzero estimate is not authorization to retain a cylinder below agency replacement requirements or to begin a transport. Plan additional oxygen and a backup supply as required by approved agency policy.

All calculations run locally in the browser. No patient identifiers or saved inputs. The host receives ordinary website requests; the app does not transmit calculator inputs. Reloading clears the fields.

The backup D cylinder and optional E cylinder are modeled independently. Their durations are not added to the primary cylinder results. If switching oxygen sources, recheck the current gauge and enter only the expected remaining time on that cylinder. Maintain backup oxygen as required by agency policy.